When we spray water, add pure water once and mixed medicine again. The medicine tank and water tank are marked on both sides of the medicine barrel; at the same time, in order to improve convenience, we can also add mixed medicine on both sides. |
How does the water mist reflect the best effect: 1. First of all, make sure that the lid of the medicine barrel cannot leak air, the air leakage does not produce mist or the mist is too small, so it must be tightened, because the medicine liquid is ejected by the air pressure, not pumped out of. 2. The valve for water and medicine is best for 1/2 atomization. It can also be fully opened or 1/3 according to the working efficiency. |
The important factors that affect the effect of water mist are closely related to the weather conditions, because 80% of water mist belongs to water vapor, and the greater the humidity of the weather. The more obvious the water mist is, the dry weather will evaporate faster, especially in summer, at noon. In the afternoon and evening, there are great distance differences between the effect and distance of water mist in different time periods. |
1. Oil exhaust air |
There will be air in the oil circuit of the new machine, and the volatilization of gasoline in the old machine for a long time will cause air in the oil circuit. |
Now we should waste some gasoline, repeatedly pressing 2 oil bubbles, the main purpose is to let the gasoline take the air out, and then start the machine. Remember: Before starting, be sure to tilt the machine 45 degrees to pour out the excess gasoline inside the machine. |
2. Manual oil supply: |
While pressing the start key, press the No. 1 oil bubble for 1-3 times with the other hand to supply oil manually. The reason is to avoid the unsmooth oil supply of the machine. The machine is not a traditional engine, the principle is special, the starting mode is a bit semi-automatic. |
3. Check the line problem: |
Press the trachea detection button to see if there is a current sound, and if the start button has a motor sound, if both buttons have sound, it is normal. |
[If it is detected that there is no sound, it is not powered]; [No sound from the start key is the motor is not powered]; [Two no sound at the same time, it is determined that the battery is dead, and it can be charged for 3 hours]. As long as there is a button, there is a sound, the battery is judged to be no problem, remove the bottom cover of the machine, check whether the thread behind the switch is loose or falling off, re-plug it again, if there is no above phenomenon, finally check the ignition needle, new machine Generally, there will be no problem. The old machine checks whether the tip of the ignition needle is oxidized. Try to replace it with a new ignition needle (new one in the kit). |
4. Check the diaphragm: |
Disassemble the carburetor base and check whether the diaphragm inside the diverter cone is broken. The fracture is not ignitable. If the fracture is replaced with a new one, pay attention to the diaphragm to block all the small holes of the diverter cone. If it doesn't catch fire, the screws should be tightened properly. |
1. First check the gas path: |
Check whether the lid of the medicine box is tight, because the liquid in the medicine barrel is ejected by the air pressure, not the pumped out. After the lid is tightened, check the air pipe for cracks, and finally check the one-way air stop valve (position: carburetor The blue plastic valve below), the function of the one-way valve is to prevent the air pressure in the medicine barrel from flowing back. Before installation, blow the test with the mouth. While venting, stop the gas, and make sure that the direction is not wrong (the tool kit is available). |
2. Check if the medicine pipeline is blocked: |
First hook out the filter in the medicine barrel with a wire, and brush it with a brush; then remove the screw at the nozzle of the water pipe and the medicine tube. There is a nozzle of about 1 mm inside. It is easy to block impurities. Just a few clicks. |
Pessoa de Contato : | Simon |
---|